EMS Manual
Distributor Errors
EMS Manual—426909-005
21-18
1047: ZEMS-ERR-BAD-EVENT
ZEMS-VAL-EMSGET 32
Cause. The distributor cannot interpret the reply from a collector following a status
request because the collector malfunctioned or aborted. This can occur when adding
an event source collector or a process that is not a collector, or during event
processing after end-of-file detection.
Effect. The distributor disconnects the failing collector but continues to run.
Recovery. Automatic source recovery is available through a special startup
parameter.
1047: ZEMS-ERR-BAD-EVENT
ZSPI-TKN-PROC-ERR
can have the following values:
ZSPI-VAL-SSGETTKN 3
ZEMS-VAL-FILTER-EVAL 20
Cause. The distributor finds the event message that it read from the log is invalid.
Effect. The distributor continues to process event messages, skipping the invalid
event. After five invalid messages are detected, event ZEMS-EVT-BAD-LOG is
generated.
Recovery. Determine how the event message got corrupted and was not detected by
the collector. An application might have generated the log, which HP does not
recommend.
1049: ZEMS-ERR-BAD-LOG
Cause. The distributor declares the current log inaccessible after five consecutive bad
event messages are encountered.
Effect. The distributor closes the file and attempts to access the next log file. If none
exist, event ZEMS-EVT-COLLECTOR-DISCONNECT is generated, and the associated
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZEMS-TKN-COLNAME token-type ZSPI-TYP-FNAME
ZEMS-TKN-LOGNAME token-type ZSPI-TYP-FNAME
ZEMS-TKN-RECORD-ADDRESS token-type ZSPI-TYP-INT2
ZSPI-TKN-PROC-ERR token-type ZSPI-TYP-ENUM
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZEMS-TKN-LOGNAME token-type ZSPI-TYP-FNAME
ZEMS-TKN-COLNAME token-type ZSPI-TYP-FNAME
ZEMS-TKN-RECORD-ADDRESS token-type ZSPI-TYP-INT2
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL