-5: ZCOM-ERR-CMD-NOT-SUPP
-5: ZCOM-ERR-CMD-NOT-SUPP
Cause. The request specifies a command that is the EMS collector does not support.
Effect. The request is not executed.
Recovery. Make sure to specify commands supported by the EMS collector.
-15: ZCOM-ERR-OBJ-ALRDY-DEF
Cause. The specified object is already configured. Because there is only one object
(filter), the user issued an ADD FILTER command, and the filter was already installed.
Effect. The filter is not added.
Recovery. To replace a filter with an updated version of the same name:
Use the SPI replace operation to replace it directly.
Delete the filter with the SPI delete operation, then add it again using the SPI
add operation.
-17: ZCOM-ERR-OBJ-NOT-FOUND
Cause. The specified object was not found.
Effect. The command does not execute because it could not find the specified object.
Recovery. Check that the object exists and that you referred to it correctly.
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL
Note. The filter order is significant, and SPI add always adds the filter to the end of the filter
list. SPI replace puts the new filter in the same place in the list as the old filter.
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL