EMS Manual
Collector Errors
EMS Manual—426909-005
22-13
1010: ZEMS-ERR-CPU-RANGE
1010: ZEMS-ERR-CPU-RANGE
Cause. A switch CPU command was issued, but the collector received a command
message with an invalid CPU number (that is, not in the range 0 through 15).
Effect. The switch does not take place.
Recovery. Specify the current backup’s CPU for the switch.
1013: ZEMS-ERR-CDIST-CPU
Cause. A switch CPU command was issued for the compatibility distributor, but the
CPU number was not equal to the backup CPU.
Effect. The switch does not take place.
Recovery. Specify the compatibility distributor’s current backup CPU for the switch.
1019: ZEMS-ERR-FLT-FORM
ZSPI-TKN-PROC-ERR
can have the values:
ZEMS-VAL-ZFILOPEN 22
ZEMS-VAL-ZFILWRITEREAD 26
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
ZSPI-TKN-PARM-ERR token-type ZSPI-DDL-PARM-ERR
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
ZSPI-TKN-PARM-ERR token-type ZSPI-DDL-PARM-ERR
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
ZEMS-TKN-FAILFILENAME token-type ZSPI-TYP-FNAME
ZEMS-TKN-FAIL-REASON token-type ZSPI-TYP-ENUM
ZEMS-TKN-FILTER-ERROR token-type ZSPI-TYP-ENUM
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL