EMS Manual

Collector Errors
EMS Manual426909-005
22-15
1034: ZEMS-ERR-OPEN-LOG
1034: ZEMS-ERR-OPEN-LOG
Cause. An ALTER collector (or CONTROL) command has been received to change
the current logging subvolume. The volume is not accessible, and the log file cannot be
created.
Effect. The collector continues to log into the current subvolume.
Recovery. Check the file system error returned and try to resolve the access problem.
1036: ZEMS-ERR-DEST-ACCESS
ZSPI-TKN-PROC-ERR
can have the value:
ZEMS-VAL-FINDDEV 39
Cause. The primary collector cannot access a TEXTOUT destination device.
Effect. The change does not occur.
Recovery. Check the command you issued for any errors in syntax or values
provided.
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
ZSPI-TKN-ZFILERR token-type ZSPI-TYP-UINT
ZEMS-TKN-FAILFILENAME token-type ZSPI-TYP-FNAME
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
ZEMS-TKN-ZFILERR token-type ZSPI-TYP-UINT
ZEMS-TKN-FAILFILENAME token-type ZSPI-TYP-FNAME
ZSPI-TKN-PROC-ERR token-type ZSPI-TYP-ENUM
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL