EMS Manual
Collector Errors
EMS Manual—426909-005
22-16
1040: ZEMS-ERR-ZFIL
1040: ZEMS-ERR-ZFIL
ZSPI-ERR-PROC-ERR
can have the values:
ZEMS-VAL-FILNM-RESOLVE 46
ZEMS-VAL-FILNM-TO-OFILNM 44
ZEMS-VAL-OFILNM-TO-FILNM 45
Cause. An ADD FILTER or ALTER FILTER command was issued for the collector, and
an I/O error occurred when attempting to read the specified filter file. This error could
be a security access error, or a nonexisting file error. The file-system error number is
reported.
Effect. The filter is not added or altered.
Recovery. Check the file name and access security of the filter.
1053: ZEMS-ERR-INV-MODE
Cause. The primary collector received a command message with an invalid mode for
the compatibility distributor: the field ZCOL-CDIST-MODE-SET, in the token map
ZEMS-MAP-COL-CONTROL-CDIST, contained an invalid value. Valid values are
ZEMS-VAL-CDIST-CRITICAL-ONLY, -CDIST-EMSMODE, and -CDIST-STOP.
Effect. The command to change mode is not executed.
Recovery. Check the command you issued for any errors in syntax or values
provided.
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
ZEMS-TKN-ZFILERR token-type ZSPI-TYP-UINT
ZEMS-TKN-FAILFILENAME token-type ZSPI-TYP-FNAME
ZSPI-TKN-PROC-ERROR token-type ZSPI-TYP-????
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
ZSPI-TKN-PARM-ERR token-type ZSPI-DDL-PARM-ERR
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL