EMS Manual

Collector Errors
EMS Manual426909-005
22-17
1054: ZEMS-ERR-CDIST-DOWN
1054: ZEMS-ERR-CDIST-DOWN
Cause. The primary collector received a CONTROL or ALTER command for the
compatibility distributor, but the distributor is not running.
Effect. The command for the distributor cannot be carried out.
Recovery. Because the compatibility distributor cannot be restarted, use a distributor
in its place.
1059: ZEMS-ERR-MAXFLT
Cause. An ADD FILTER command was issued causing the maximum number of filters
(10) to be exceeded.
Effect. The filter is not added.
Recovery. Remove filters first to accommodate the new filter.
1060: ZEMS-ERR-FLT-ALLOC
Cause. An ADD FILTER command was issued, and the combined resources for event
source, destination, and filter parameter buffers exceed the buffer pool size.
Effect. The filter is not added.
Recovery. Remove sources, destinations, and filters to reduce the buffer pool size.
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
ZSPI-TKN-PARM-ERR token-type ZSPI-DDL-PARM-ERR
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
ZEMS-TKN-FAILFILENAME token-type ZSPI-TYP-FNAME
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL