1053: ZEMS-ERR-INV-MODE
1053: ZEMS-ERR-INV-MODE
Cause. The primary collector received a command message with an invalid mode for
the compatibility distributor: the field ZCOL-CDIST-MODE-SET, in the token map
ZEMS-MAP-COL-CONTROL-CDIST, contained an invalid value. Valid values are
ZEMS-VAL-CDIST-CRITICAL-ONLY, -CDIST-EMSMODE, and -CDIST-STOP.
Effect. The command to change mode is not executed.
Recovery. Check the command you issued for any errors in syntax or values
provided.
1054: ZEMS-ERR-CDIST-DOWN
Cause. The primary collector received a CONTROL command for the compatibility
distributor, but the distributor is not running.
Effect. The command for the distributor could not be carried out.
Recovery. Because the compatibility distributor cannot be restarted, use a distributor
in its place.
1055: ZEMS-ERR-NO-BACKUP
Cause. The content of the ZCOL-PRIMARYCPU field was the alternate collector's
backup CPU, but the alternate collector does not currently have a backup process.
Effect. The command is not executed.
Recovery. Determine whether the backup was created or if it simply has not started. If
necessary, stop the alternate collector and restart it so it automatically creates a new
backup process.
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZSPI-TKN-PARM-ERR token-type ZSPI-DDL-PARM-ERR
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZSPI-TKN-PARM-ERR token-type ZSPI-DDL-PARM-ERR
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZSPI-TKN-PARM-ERR token-type ZSPI-DDL-PARM-ERR
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL