Envoy ACP/XF Configuration and Management Manual
Subsystem Control Facility (SCF) Commands for
EnvoyACP/XF
EnvoyACP/XF Configuration and Management Manual—429232-003
5-8
ALTER DEVICE Command
CLIP clip-num
indicates which CLIP the DEVICE object will use. Possible values are 1, 2, or 3.
HIGHPIN ON | OFF
indicates whether the data communications subsystem object is to be run highpin.
The default is ON.
IOPOBJECT object-file-name
indicates the file name of the executable object code for the data communications
subsystem object.
LINE line-num
selects the line number on the selected CLIP to be used by the DEVICE.
line-num must not have been previously selected for use by another DEVICE.
The possible values are 0 or 1.
modifier-keyword [ modifier-value ]
modifier-keyword and modifier-value specify product-specific
characteristics for the DEVICE object. modifier-keyword specifies a keyword
defined in profile-name, and modifier-value specifies a string of characters
associated with the specified modifier-keyword.
PATH path-name
indicates which Ethernet path on the SWAN concentrator to use. Possible values
are A or B. A indicates the A Ethernet path. B indicates the B Ethernet path.
RECSIZE | RSIZE max-rec-size
max-rec-size is supported by each DEVICE object. This value is returned by the
GET_DEVICE_INFO_ calls issued for the DEVICE once it has been started. If you
don’t provide a default value, the default in the PROFILE object is used.
RESET [ ( modifier-keyword [ modifier-keyword ... ] ) ]
resets the specified modifier (or modifiers) back to its default value. The
parenthesis are required if more than one modifier is specified. If no modifiers are
specified, then all modifiers are reset to their default values.
TYPE type , sub-type
indicates the NonStop Kernel registered type and subtype for the DEVICE object.