Envoy ACP/XF Configuration and Management Manual
Subsystem Control Facility (SCF) Commands for
EnvoyACP/XF
EnvoyACP/XF Configuration and Management Manual—429232-003
5-13
ALTER LINE Command
EXTENDEDCONTROL
specifies the selection of a basic or extended control field for frames transferred on
the communication link.
FLAGFILL
specifies whether flag characters are transmitted continuously between frames.
FRAMESIZE
specifies the maximum size, in words, of read and write buffers for the line.
IDLECMDRR
specifies that an RR frame is sent at specific intervals on an ABM line that uses the
primary address with the P/F bit not set.
IDLETIMER
specifies the time between polling cycles for a primary station. For combined
stations, specifies the time between RR frames on an idle line.
INTERFACE
specifies the electrical interface to the line (RS-232 or RS-449).
Default OFF
Range ON | OFF
Default OFF
Range ON | OFF
Default 268
Range 75 to 2042
Default OFF
Range ON | OFF
Note Only for ABM
Default 50
Range 2 to 32767
Units 10 milliseconds
Default RS232
Range RS232 | RS422
Note. See the WAN Subsystem Configuration and Management Manual to ensure that the
correct cable for the interface is attached to the WAN port.