Envoy Application Programming Manual
Table Of Contents
- What’s New in This Manual
- About This Manual
- 1 Application Programming With Envoy
- 7 ADM-2 Multipoint Supervisor Protocol
- 8 TINET Multipoint Supervisor Protocol
- 9 Burroughs Point-To-Point Protocol
- 10 Asynchronous Line Supervisor Protocol
- A ASCII Character Set
- B ASCII to EBCDIC Code Conversion
- C File-System Procedures
- D Statistics Messages
- E S-Series Changes to Envoy
- NonStop™ Himalaya S-Series Server Architecture
- G-Series Migration Considerations
- CBSENSEON and CFSENSEON Modifiers
- LEOTRESYN and NOLEOTRESYN Modifiers
- Treatment of Characters After the Termination Character
- Number of SYN Characters
- DTR Drop
- Reporting of Parity Error
- Half-Duplex Support for Asynchronous Lines
- Controller Replacement
- SYSGEN and COUP
- Unit Numbers
- FDX Line Changes
- No Support for Auto-Call Unit
- Glossary
- Index
ADM-2 Multipoint Supervisor Protocol
Envoy Application Programming Manual—427159-001
7-15
Polling Interval
Polling Interval
The polling interval specifies a time interval that Envoy waits, following a pass through
the poll list, before beginning a subsequent pass through the poll list. Figure 7-5 shows
the use of the polling interval.
The polling interval is specified for a communications line when issuing the ADD
DEVICE command and can be altered with a call to the SETMODE procedure.
The time interval between the polling of terminals during a pass through the poll list is
determined by the length of time that individual terminals take to respond to the poll.
Figure 7-5. ADM-2 Multipoint Supervisor Polling Interval
046CDT .CDD
CALL READ...
CALL OPEN...
CALL DEFINELIST...
Poll Entry 0
Poll Entry 1
EOT
EOT
Done?
Delay for Poll
Interval
Poll Entry pn-1
EOT
No
Yes