Envoy Application Programming Manual
Table Of Contents
- What’s New in This Manual
 - About This Manual
 - 1 Application Programming With Envoy
 - 7 ADM-2 Multipoint Supervisor Protocol
 - 8 TINET Multipoint Supervisor Protocol
 - 9 Burroughs Point-To-Point Protocol
 - 10 Asynchronous Line Supervisor Protocol
 - A ASCII Character Set
 - B ASCII to EBCDIC Code Conversion
 - C File-System Procedures
 - D Statistics Messages
 - E S-Series Changes to Envoy
- NonStop™ Himalaya S-Series Server Architecture
 - G-Series Migration Considerations
- CBSENSEON and CFSENSEON Modifiers
 - LEOTRESYN and NOLEOTRESYN Modifiers
 - Treatment of Characters After the Termination Character
 - Number of SYN Characters
 - DTR Drop
 - Reporting of Parity Error
 - Half-Duplex Support for Asynchronous Lines
 - Controller Replacement
 - SYSGEN and COUP
 - Unit Numbers
 - FDX Line Changes
 - No Support for Auto-Call Unit
 
 
 - Glossary
 - Index
 

TINET Multipoint Supervisor Protocol
Envoy Application Programming Manual—427159-001
8-15
Polling Interval
Polling Interval 
The polling interval specifies a time interval that Envoy waits, following a pass through 
the poll list, before beginning a subsequent pass through the poll list. Figure 8-5 shows 
the use of the polling interval.
The polling interval is specified for a communications line when issuing the ADD 
DEVICE command. You can alter the polling interval by calling the SETMODE 
procedure.
The time interval between the polling of terminals during a pass through the poll list is 
determined by the length of time individual terminals take to respond to the poll.
Figure 8-5. TINET Multipoint Supervisor Polling Interval Poll State
046CDT .CDD
CALL READ...
CALL OPEN...
CALL DEFINELIST...
Poll Entry 0
Poll Entry 1
EOT
EOT
Done?
Delay for Poll
Interval
Poll Entry pn-1
EOT
No
Yes