Envoy Configuration and Management Manual
WAN Subsystem Profiles and Modifiers for Envoy
Envoy Configuration and Management Manual—429861-001
3-12
Modifier Descriptions
CL
Default: EIA
Units: Not applicable
Range: Not applicable
Alternate modifier: EIA
This modifier applies to ADM, TINET, SIMPLEX, and ASC lines only. It defines the
electrical connection type as current-loop.
CLEARCA
Default: CLEARCA
Units: Not applicable
Range: Not applicable
Alternate modifier: NOCLEARCA
This modifier applies to BSC lines only. It specifies to clear the CA from write to send.
CLEARRTS
Default: ON
Units: Not applicable
Range: Not applicable
Alternate modifier: None
This modifier applies to BSC lines only. It specifies to clear the CA (RTS) from write to
send.
COMPARE_OFF
Default: COMPARE_OFF
Units: Not applicable
Range: Not applicable
Alternate modifier: None
This modifier has no affect on the line. It cannot be altered.
This modifier cannot be removed from the device record.
Note. This modifier is similar to the CLEARCA/NOCLEARCA device modifiers.