Envoy Configuration and Management Manual

WAN Subsystem Profiles and Modifiers for Envoy
Envoy Configuration and Management Manual429861-001
3-20
Modifier Descriptions
IDLETIMER n
Default: 1000
Units: 0.01 seconds
Range: 300 to 32727
Alternate modifier: None
This modifier applies to all Envoy line types. It specifies the interval for probing the
status of the data link control (DLC) task during periods of inactivity between the Envoy
line-handler process and the DLC task.
INSPECT
Default: INSPECTOFF
Units: Not applicable
Range: Not applicable
Alternate modifier: INSPECTOFF
This modifier applies to all Envoy line types. It causes the Envoy subsystem to enter
Inspect when the Envoy line-handler process is started. This modifier should only be
used for debugging purposes.
INSPECTOFF
Default: INSPECTOFF
Units: Not applicable
Range: Not applicable
Alternate modifier: INSPECT
This modifier applies to all Envoy line types. It causes the Envoy subsystem not to enter
Inspect when the Envoy line-handler process is started.
ITBSIZE n
Default: 0
Units: Not applicable
Range: 0 to 32727
Alternate modifier: None
This modifier applies to BSC and ADM lines only. It sets the intermediate block size. It
can be altered with a call to SETMODE 17.