Envoy Configuration and Management Manual

WAN Subsystem Profiles and Modifiers for Envoy
Envoy Configuration and Management Manual429861-001
3-35
Modifier Descriptions
STOPBITON
Default: STOPBITOFF
Units: Not applicable
Range: Not applicable
Alternate modifier: STOPBITOFF
This modifier applies to TINET, SIMPLEX, ADM, and ASC lines only. It specifies that
an extra stop bit is generated. Each character has either 1.5 or 2 stop bits depending on
the baud rate.
SUBTYPE
Default: None
Units: Not applicable
Range: Not applicable
Alternate modifier: Not applicable
This modifier identifies each Envoy line. Table 3-2
on page 3-2 shows the TYPE and
SUBTYPE values for Envoy lines. Protocol is automatically added, depending upon
SUBTYPE, if not specified.
SWIFT
Default: Not specified
Units: Not applicable
Range: Not applicable
Alternate modifier: None
This modifier applies to BSC lines only. It specifies that BCC calculation is done
according to the SWIFT protocol.
Once this modifier is added to the device record, it can only be removed by using the
SCF ALTER DEVICE command with the RESET modifier option.
SWITCH
Default: Not specified
Units: Not applicable
Range: Not applicable
Alternate modifier: None
This modifier applies to SIMPLEX lines only. It enables CD control by application
(DTR).