Relocating an E4SA
Ethernet Adapter Installation and Support Guide—425684-003
4-24
Remove and Install the Adapter
Remove and Install the Adapter
The following steps describe how to remove an E4SA and then install it in a new
location.
1. Disconnect the communications cables from the E4SA.
2. Put on your electrostatic discharge (ESD) wriststrap and connect the grounding clip
securely to an exposed, unpainted, metal surface on the service side of the system
enclosure, such as the processor multifunction (PMF) CRU or I/O multifunction
(IOMF) CRU ventilation holes
The figure shows how to connect the grounding clip to the ventilation holes on the
PMF or IOMF CRU.
3. Unlatch the ejector on the E4SA by pressing the blue-green tab on the ejector and
pulling the ejector outward to unseat the E4SA from the backplane.
4. Grasp the E4SA by its ejector in one hand and slowly pull the E4SA out of the slot
while supporting the bottom edge of the E4SA with the other hand.
Figure 4-5. Grounding Clip
Note. The E4SA weighs 6.75 pounds (3 kilograms).
081CDT .CDD
Processor Multifunction (PMF) CRU or
I/O Multifunction (IOMF) CRU
Grounding
Clip
To Grounding
Wriststrap