Installing a New E4SA
Ethernet Adapter Installation and Support Guide—425684-003
2-8
Install the New E4SA
Install the New E4SA
You should perform the hardware installation first and then add the adapter using the
Subsystem Control Facility (SCF). You can use SCF to add the adapter first and then
insert the hardware. Whichever installation method you choose, the state of a logical
interface (LIF) is not affected by the physical presence, or absence, of an adapter. If
you decide to configure the adapter and its LIFs before the E4SA is inserted into the
enclosure, the ServerNet addressable controllers (SACs) and physical interfaces
(PIFs) of the adapter will remain in the starting state; the LIF will be in the started state,
but its access state will be down until its associated PIF is started. The following
subtopics describe the tasks associated with physically inserting the E4SA into a
NonStop S-series system enclosure and using the SLSA subsystem to logically add
and start the E4SA:
•
Unpack and Install the New E4SA
•
Check the Installation of the New E4SA
•
Add and Start the E4SA Using SCF
Unpack and Install the New E4SA
The following paragraphs describe how to unpack and install the new E4SA.
Unpack the E4SA
The following explains how to unpack the E4SA:
1. Put on the electrostatic discharge (ESD) wriststrap and attach the grounding clip to
the antistatic mat.
2. Place the package containing the E4SA on the antistatic mat.
3. Open the packing container and remove the E4SA.
4. Disconnect the grounding clip of your ESD wriststrap from the antistatic mat and
connect it to an exposed, unpainted metal surface on the E4SA.
5. Grasp the E4SA by its ejector in one hand, support the bottom edge of the E4SA
with the other hand, and carry the E4SA to the service side of the system
enclosure and set it down.
Note. Whenever you handle an Ethernet 4 ServerNet adapter (E4SA), you should follow
standard operating practices to avoid damage to the equipment. See Review Standard
Operating Practices on page 2-7.
Caution. When opening the packing container, be careful not to cut into the ESD protective
bag.
Note. The E4SA weights 6.75 pounds (3 kilograms)