Ethernet Adapter Installation and Support Guide
Replacing an E4SA
Ethernet Adapter Installation and Support Guide—425684-003
3-2
Prepare to Replace an E4SA
Prepare to Replace an E4SA
E4SAs can be installed in slots 53 and 54 of a processor enclosure and in slots 51, 52,
53, and 54 of an I/O enclosure. See Figure 3-3 on page 3-20. When no E4SA is
installed in a slot, a ServerNet adapter filler panel occupies the empty slot. (Therefore,
a ServerNet adapter filler panel can possibly occupy slots 53 and 54 of a processor
enclosure or slots 51 through 54 of an I/O enclosure.) The filler panel maintains proper
air flow and reduces electromagnetic interference (EMI).
Table 3-1 summarizes the steps for preparing to replace an E4SA.
Gather the Proper Tools
You will need the following tools to replace an adapter:
Note. E4SAs (including E4SA connections via S-series I/O enclosures) are not supported on
NonStop BladeSystems.
Table 3-1. Preparation Checklist
Step Description Comments
1.
Gather the Proper Tools.
2.
Print the E4SA Planning Worksheets. Figure 3-1 and Figure 3-2
3.
Identify Any Communications Lines and ServerNet
Wide Area Network (SWAN) Using the E4SA.
4.
Redirect or Stop Any Customer Applications Using
the E4SA.
5.
Stop the Communications Lines and SWAN
Concentrator Lines Using an E4SA.
6.
Determine the Physical Location of the E4SA.
7.
Abort the E4SA.
8.
Label the Communications Cables Connected to the
E4SA.
Tool Used to. . .
Electrostatic discharge
(ESD) wriststrap with
grounding clip
Protect the adapter from damage caused by
electrostatic discharge.
Antistatic mat
(recommended)
Provide a static-free environment for removal and
installation of an adapter.
Flashlight Check the connectors for bent or broken pins.