Replacing an E4SA
Ethernet Adapter Installation and Support Guide—425684-003
3-19
Label the Communications Cables Connected to the
E4SA
3. Abort the E4SA object and its subordinate objects. You can use either SCF or the
TSM Service Application to perform this step.
a. Using SCF to Abort the Adapter:
Use the SCF ABORT ADAPTER command with the SUB ALL option The SUB
ALL option aborts the ADAPTER object and all its subordinate objects.
ABORT ADAPTER $adapter-name, SUB ALL
b. Using the TSM Service Application to Abort the Adapter:
1. Log on to the TSM Service Application.
2. In the Tree view, select the E4SA.
3. From the Display menu, choose Actions.
4. Select Abort.
5. Click Perform action.
4. Verify that the E4SA ADAPTER object is in the STOPPED state.
Use the SCF STATUS ADAPTER command:
STATUS ADAPTER $adapter-name
Example 3-24 shows the output of this command. Note that the ADAPTER
(E0153) is in the STOPPED state.
Label the Communications Cables Connected to the E4SA
To label communications cables for an E4SA:
1. Find the group, module, and slot in which the Ethernet 4 ServerNet adapter (E4SA)
is installed.
Figure 3-3 on page 3-20 shows the E4SA slot locations.
Example 3-24. SCF STATUS ADAPTER Command
->STATUS ADAPTER $ZZLAN.E0153
SLSA Status ADAPTER
Name State
$ZZLAN.E0153 STOPPED