Ethernet Adapter Installation and Support Guide
Replacing an E4SA
Ethernet Adapter Installation and Support Guide—425684-003
3-31
Resume Operations
Resume Operations
The following describes starting the new E4SA.
Start the New E4SA
Start the Ethernet 4 ServerNet adapter (E4SA) ADAPTER object and its subordinate
SAC and PIF objects.
You can use either SCF or the TSM Service Application to start the E4SA.
Using SCF to Start the E4SA
Use the SCF START ADAPTER command with the SUB ALL option. The SUB ALL
option starts the ADAPTER object and its subordinate objects.
START ADAPTER $adapter-name, SUB ALL
Using the TSM Service Application to Start the E4SA
1. Log on to the TSM Service Application.
2. In the
Tree view, select the E4SA.
3. From the Display menu, choose Actions.
4. Select Start.
5. Click Perform action.
Table 3-3. Resuming Operations Checklist
Step Description Comments
1.
Start the New E4SA
2.
Restart the Communications Lines See Note below.
3.
Verify that the Communications Lines are Restarted
4.
Resume Customer Applications
Note. You need to perform this step if you stopped communications lines or if an IPXPROTO
process was using the E4SA CRU that was replaced. IPXPROTO processes must be manually
restarted after an E4SA CRU is replaced.