Ethernet Adapter Installation and Support Guide
Replacing an E4SA
Ethernet Adapter Installation and Support Guide—425684-003
3-35
Verify that the Communications Lines are Restarted
Use the SCF START LINE command with the SUB ALL option. The SUB ALL
option starts the LINE object and its subordinate objects.
START LINE $line-name, SUB ALL
4. Start an Expand-over-IP line.
a. Start the WAN subsystem input/output process (IOP).
Use the SCF START DEVICE command:
START DEVICE $ZZWAN.#device-name
b. Start the line(s).
1. Use the SCF START LINE command to start a single line:
START LINE $line-name
2. Use the SCF START PATH command to start all the lines in an Expand
multiline path:
START PATH $line-name
5. Start the ServerNet wide area network (SWAN) concentrator and its associated
WAN subsystem IOPs and communications lines:
a. Start the SWAN concentrator.
Use the SCF START ADAPTER command with the SUB ALL option:
START ADAPTER $ZZWAN.#adapter-name, SUB ALL
b. Start the WAN subsystem IOPs.
Use the SCF START DEVICE command:
START DEVICE $ZZWAN.#device-name
c. Start the line(s).
1. Use the SCF START LINE command to start a single line:
START LINE $line-name
2. Use the SCF START PATH command to start all the lines in an Expand
multiline path:
START PATH $path-name
Verify that the Communications Lines are Restarted
Verify that communications lines using an E4SA are started: