Ethernet Adapter Installation and Support Guide
Relocating an E4SA
Ethernet Adapter Installation and Support Guide—425684-003
4-2
Prepare to Relocate an E4SA
Prepare to Relocate an E4SA
E4SAs can be installed in slots 53 and 54 of a processor enclosure and in slots 51, 52,
53, and 54 of an I/O enclosure. See Figure 4-3 on page 4-21. When no E4SA is
installed in a slot, a ServerNet adapter filler panel occupies the empty slot. (Therefore,
a ServerNet adapter filler panel can possibly occupy slots 53 and 54 of a processor
enclosure or slots 51 through 54 of an I/O enclosure.) The filler panel maintains proper
air flow and reduces electromagnetic interference (EMI).
Table 4-1 summarizes the steps for preparing to relocate an E4SA.
Note. E4SAs (including E4SA connections via S-series I/O enclosures) are not supported on
NonStop BladeSystems.
Note. You can configure the Parallel Library TCP/IP and NonStop TCP/IPv6 subsystems with
the Ethernet failover feature, which provides fault-tolerance at the adapter level. If you want to
be able to later replace the E4SA without halting TCP/IP communications, configure the
Ethernet failover pair on LIFs belonging to different adapters.
Table 4-1. Preparation Checklist
Step Description Comments
1.
Gather the Proper Tools.
2.
Print the E4SA Planning Worksheets. Figure 4-1 and Figure 4-2
3.
Identify Any Communications Lines and ServerNet
Wide Area Network (SWAN) Using the E4SA.
4.
Redirect or Stop Any Customer Applications Using
the E4SA.
5.
Stop the Communications Lines and SWAN
Concentrator Lines Using an E4SA.
6.
Determine the Physical Location of the E4SA.
7.
Stop the E4SA.
8.
Label the Communications Cables Connected to the
E4SA.