Event Management Service (EMS) Analyzer Manual
Command Descriptions
Event Management Service (EMS) Analyzer Manual–133700
5-32
INFO
Examples 
The following is a sample of output of the INFO command used on EMS Analyzer’s 
own distributor with the default filter (EMSAFLTR). 
•
Distributor type is the type of distributor (CONSUMER, FORWARDING, 
or PRINTING).
•
Filter is the name of the filter to be used when searching for events.
•
Emslog is the name of the EMS events source file.
•
Coll log is the name of a collector log file. This is displayed only if the 
distributor is in collector mode.
•
Current log is the name of the current collector log file. This is displayed only 
if the distributor is in collector mode.
•
EventDB is the name of an Enscribe data base or CSV file. The selected events are 
written to this file.
•
EventDB type is the type of the data base or CSV file. It can be Enscribe, CSV, 
or blank if a value is not specified for the EventDB attribute.
•
EventDB extents is the current default values for Primary and Secondary 
extent size, and for Maximum number of extents. These values are assumed when 
creating a new database or CSV file if values are not specified for the extents 
options.
•
Format is the display format of the selected events on the current output 
destination. It can be TEXT, TOKEN or both. TOKEN can have the DETAIL option.
-> INFO DISTRIBUTOR $dist
-> INFO /OUT OutInfo/ DISTRIBUTOR $dist
-> INFO DISTRIBUTOR $Z464
EMSA INFO DISTRIBUTOR $Z464
Distributor type. CONSUMER
*Filter.......... $STING.EMSA.EMSAFLTR
*Emslog.......... $0.#ZSPI
Coll log......... $SYSTEM.ZLOG00.ZZEV0004
Current log...... $SYSTEM.ZLOG00.ZZEV0004
*EventDB.........
*EventDB type....
*EventDB extents. (20,100,16)
*Format.......... TEXT
*Dumplog Status.. 5 seconds
Search criteria
*Starttime... 91JUL25, 00:00:00  *Stoptime.. EOF
*Eventnumber. 123    *Eventtype. ALL
*Processid...     *SSid...... cttm.1.0
*System...... \POLLUX    *Ldev......
*Text........