Event Management Service (EMS) Analyzer Manual

Event Data File Record Definition
Event Management Service (EMS) Analyzer Manual133700
A-2
Enscribe Database File
console-print CHARACTER 1 Corresponds to the ZEMS-TKN-CONSOLE-
PRINT token of the EMS Analyzer event buffer.
The default value is space.
emphasis CHARACTER 1 Corresponds to the ZEMS-TKN-EMPHASIS
token of the EMS Analyzer event buffer. It will
have the value “T” if this is a critical; otherwise,
it is “F”. The default value is space.
subjtype BINARY 16 Corresponds to the data type of the first subject
token of the EMS Analyzer event buffer. The
default value is 0.
subjlen BINARY 16 Corresponds to the length of the first subject
token of the EMS Analyzer event buffer. The
default value is 0.
subject CHARACTER 35 Corresponds to the first subject after the ZEMS-
TKN-SUBJECT-MARK in the EMS Analyzer
event buffer. The default value is spaces.
senderid CHARACTER 35 Corresponds to the ZEMS-TKN-SENDERID
token of the EMS Analyzer event buffer. The
default value is spaces.
manager CHARACTER 35 Corresponds to the ZSPI-TKN-MANAGER
token found in the EMS Analyzer event buffer.
The default value is spaces.
textlen BINARY 16 Corresponds to the length of the text message
generated by the EMSTEXT procedure on the
EMS Analyzer event buffer. The default value is
0.
text CHARACTER 200 Corresponds to the text message generated by
the EMSTEXT procedure on the EMS Analyzer
event buffer. The default value is spaces.
Table A-1. EMS Analyzer Event Data File Record Definition - Enscribe
Database (page 2 of 2)
Field Name Data Type Description