Event Management Service (EMS) Analyzer Manual
Error Messages
Event Management Service (EMS) Analyzer Manual–133700
E-7
Error Messages
EMSA 20060 
Cause. The system monitor process is currently unavailable.
Recovery. Usually no recovery is necessary. If further problems exist, then consult your 
system manager.
EMSA 20061 
Cause. The program and library files are identical.
Recovery. Reissue the command with the correct library name.
EMSA 20062 
Cause. A NonStop Kernel error occurred while attempting to allocate an extended 
segment.
Recovery. Use the ERROR program for an explanation of the file-system error.
EMSA 20063 
Cause. A NonStop Kernel error occurred while attempting to allocate an extended 
segment.
Recovery. Use the ERROR program for an explanation of the file-system error.
EMSA 20064 
Cause. The home terminal specified in the RUN command was not a legal terminal. 
Recovery. Specify a valid terminal name.
NEWPROCESS error 10: Unable to communicate with system 
monitor 
 process
NEWPROCESS error 12: Program file and library file cannot be 
 the same
NEWPROCESS error 13: Extended data segment initialization 
 error (GUARDIAN error <n>)
NEWPROCESS error 14: Extended segment swap file error 
 (GUARDIAN error <n>)
NEWPROCESS error 15: Illegal home terminal (GUARDIAN error 
<n>)