Event Management Service (EMS) Analyzer Manual

Error Messages
Event Management Service (EMS) Analyzer Manual133700
E-23
Error Messages
EMSA 20328
Cause. The specified maximum extent value is not valid.
Recovery. Specify a value in the range [0..978].
EMSA 20329
Cause. The event could not be decoded because of an SPI error.
Recovery. Contact your Tandem representative.
EMSA 20330
Cause. There was an option that was specified twice in the command.
Recovery. Specify any option only once.
EMSA 20331
Cause. The value specified for priority is not valid.
Recovery. Specify a value in range [1..199].
EMSA 20332
Cause. The specified distributor name is not valid for EMSA subsystem.
Recovery. Specify a valid distributor name.
EMSA 30013
Cause. The configuration for the distributor contains an invalid file name.
Recovery. Verify with the INFO
command that all parameters have the correct value.
The maximum extent value must be in the range [0..978]
SPI error <nnn> occurred while trying to get <token>
Same option specified twice in input command line
The priority value must be in the range [1..199]
This distributor name is not supported by EMSA: \*
Invalid file name