Event Management Service (EMS) Analyzer Manual

Error Messages
Event Management Service (EMS) Analyzer Manual133700
E-30
Error Messages
EMSA 31020
Cause. The distributor could not load the filter.
Recovery. Make sure the FILTER attribute is a valid filter file. If the problem persists,
contact your Tandem representative.
EMSA 31022
Cause. One or more filter parameter tokens are missing.
Recovery. Try the command again and if the problem persists, contact your Tandem
representative.
EMSA 31024
Cause. The distributor cannot perform this operation in logfile mode.
Recovery. Specify an EMSLOG collector for this operation.
EMSA 31025
Cause. The distributor cannot connect another collector because the number of
collectors was already at its maximum (5).
Recovery. EMS Analyzer allows only one EMS source collector at a time. Reset the
EMSLOG attribute to its default value ($0), then specify the desired EMS source
collector.
EMSA 31026
Cause. The collector is already associated with the distributor and cannot be connected.
Recovery. No specific action required.
Filter could not be loaded by distributor
Filter parameter missing
Operation cannot be performed with an EMS log file as event
source
Maximum collector number reached
The collector (EMSLOG) is already associated with the
distributor