Event Management Service (EMS) Analyzer Manual

Error Messages
Event Management Service (EMS) Analyzer Manual133700
E-37
Interprocess Communication Error Messages
-00012
Cause. A fixed limit or configuration limit was exceeded. Generally, this error is used
to report any overrun of a limit, including internal control blocks or tables.
Recovery. The recovery action is dependent on the limit exceeded. Refer to the
subsystem specific reference manual for the subsystem with which you are
communicating for information about recovery from this error.
-00013
Cause. A fixed limit or configuration limit was exceeded. Generally, this error is used
to report any overrun of a limit, including internal control blocks or tables.
Recovery. Recovery is hardware-specific; check the modem, port, and so forth.
-00014
Cause. The target subsystem is unable to obtain memory space.
Recovery. Typically, this error indicates a resource-availability problem caused by a
large amount of activity (assuming that the configuration is proper for the operating
environment, and that the associated hardware is functioning normally). Attempt to
determine and correct the problem, or wait a while before reissuing the request.
-00017
Cause. The specified object name could not be found within the subsystem. Usually
this means the object has not been added yet. This error situation includes the case
where a command refers explicitly to an object and no object of that type is supported by
the target subsystem.
Recovery. Add the device first, correct the object name or correct the object type.
Maximum Limit Exceeded: <limit number> for <obj name>
<number> Modem Error: <number> signal loss
Unable To Obtain Memory: <text> for <obj name>
Object <name> Not Found