Event Management Service (EMS) Analyzer Manual

Error Messages
Event Management Service (EMS) Analyzer Manual133700
E-38
Interprocess Communication Error Messages
-00018
Cause. This object type is not supported. An invalid, unknown, or unsupported object
type was encountered.
Recovery. Refer to the subsystem specific reference manual for the subsystem with
which you are communicating for information about the object types supported by that
subsystem.
-00019
Cause. An invalid object name template was found in the command buffer.
Recovery. Correct the object name syntax and reissue the request.
-00020
Cause. Unexpected loss of the link between objects.
Recovery. Recovery is subsystem specific. Refer to the subsystem specific reference
manual for the subsystem with which you are communicating for information about
recovery from this error condition.
-00021
Cause. A SWITCH command was issued against a resource that is unknown to the
target subsystem.
Recovery. Check for the correct configuration. Then, reissue the command against the
proper resource.
-00022
Cause. A sensitive command request was attempted by a user unauthorized to issue
such a command.
Recovery. If possible, acquire the proper security and reissue the request.
Object type is not supported by this subsystem
Invalid object name: <name>
Path <path> is inaccessible for <obj name>
Resource <text> is not configured for <obj name>
Security violation for <obj name>