Event Management Service (EMS) Analyzer Manual

Error Messages
Event Management Service (EMS) Analyzer Manual133700
E-40
Interprocess Communication Error Messages
-00029
Cause. A command was issued in which a required token is missing.
Recovery. Contact your Tandem representative.
-00030
Cause. An illegal value was encountered in a supported token.
Recovery. Recovery action is dependent on the token in error and on the value specified
in that token. Refer to the subsystem specific reference manual for the subsystem with
which you are communicating for information about recovery from this error.
-00031
Cause. A required attribute value was omitted.
Recovery. Supply the required value and reissue the request.
-00032
Cause. A command request was issued in which the command version was a higher
level than the version of the target subsystem, and the command contained tokens
unknown to the subsystem. Also, this error can occur if the version of a field in a
structured token is a higher level than the version of the target subsystem.
Recovery. Communication with the subsystem is not possible. Refer to the DSM/SCM
Event Management Programming Manual for information about recovery from version
incompatibility. The experienced user may be able to do a VERSION
command and
determine what part of the original command can be modified such that the command
can be issued successfully.
Internal Error: Required token Missing: Token Code: <HEX num>
(tnm:<num>)
Internal Error: Invalid Value: <text> (tnm:<num>, Offset:
<num>) for <obj name>
Required Value Missing for Attribute: <text> (tnm:<num>,
Offset: <num>)
Incompatible Version: <num>, Command required subsystem to be
<num> for <obj name>