Event Management Service (EMS) Analyzer Manual

Using EMS Analyzer
Event Management Service (EMS) Analyzer Manual–133700
3-4
Running EMS Analyzer
The EMS Analyzer prompt is the arrow (->), but you can modify the prompt by using
the SETPROMPT command.
The syntax for the RUN command follows:
RUN
is the TACL RUN command.
EMSA
is the program file name of the EMS Analyzer program.
run-option
is one of the following. This list describes commonly used RUN options. For a
complete list of RUN options, see the Tandem Advanced Command Language
(TACL) Reference Manual.
CPU cpu-number
specifies the number of the CPU in which EMS Analyzer is to run. cpu-
number is an integer in the range of 0 through 15. If you omit this option, EMS
Analyzer runs in the same processor as TACL. (If the CPU option is omitted and
a $CMON process exists, $CMON might specify a CPU other than the one in
which the current TACL process is running. For more information about
$CMON, see the Guardian Programmer’s Guide.)
IN [ file-name ]
specifies the input file for the EMS Analyzer process. If you do not include the
IN file-name, EMS Analyzer uses the IN file in effect for the current TACL
(usually your home terminal).
NAME [ $process-name ]
specifies the name you are assigning to EMS Analyzer. Specify the
$process-name as an alphanumeric string of 1 to 5 characters, the first of
EMSA - T9671C30 - (01NOV91) (15DEC91) - 11/20/91 18:22:33 System \MTL
Copyright Tandem Computers Incorporated 1991
(Invoking $SYSTEM.STARTUP.EMSACSTM)
Confirm....... ON
EMSA CONSUMER DISTRIBUTOR $Z902 started
EMSA DISTRIBUTOR $Z902 altered: EMSLOG attribute
EMSA DISTRIBUTOR $Z902 altered: FILTER attribute
DISTRIBUTOR $Z902 1->
[ RUN ] EMSA [ / run-option / ]
[ command [ ; command ] ... ]