Event Management Service (EMS) Analyzer Manual

Using EMS Analyzer
Event Management Service (EMS) Analyzer Manual133700
3-31
Viewing Events in Token Format—No Header
Tokens
Example
Viewing Events in Token Format—No Header Tokens
To set the EMS Analyzer environment so that all selected EMS event messages are
displayed in token format on the screen, but the header tokens are not displayed, type the
following at the prompt:
-> alter, format token
-> dumplog
This command sets the format attribute so that header tokens are not displayed.
The DUMPLOG command starts the search.
DISTRIBUTOR $Y200 -> alter, format token detail
EMSA DISTRIBUTOR $Y200 altered: FORMAT attribute
DISTRIBUTOR $Y200 -> dumplog
Searching events...
--------------------------------------------------------------------------
-----
Header Type: 1
Checksum: F
Last Error: no error (0)
Last Error Tkncode: (0,0,0)
Max Field Version: 0
SSID: TANDEM.127.C30
Used Byte Length: 286
Buffer Byte Length: 286
Console Print: F
Generating-CPU: 0
Crtpid: $OMF1
Emphasis: T
Event Number: 101
ZEMS-TKN-FORWARDED: F
Generation Timestamp: 1991-09-10 14:59:55.442.284
Logged Timestamp: 1991-09-10 14:59:55.636.255
PIN: 91
ZEMS-TKN-REDUNDANT: F
Suppress Display: F
System Number: 247
Userid: 255 255
Subject Mark: *
(2,2,500): 0
TANDEM.EMS.0 Text: "OMF: CPU 00, Current State = OVER THRESHOLD,
Prev"
"ious State = UP, Current Usage = 96,
Configured T"
"threshold = 90, Sampling Interval = 1
minutes."
(2,2,100): 1
(2,2,200): 1
(2,2,300): 1
(2,2,400): 0
(2,2,1600): 90
(2,2,1700):- 96
--------------------------------------------------------------------------
-----