5-10
ALTER
FORMAT [ TEXT | TOKEN [detail] ] [ TEXT | TOKEN [detail] ]
specifies in which format(s) the selected EMS events display on the screen. At most,
two values can be specified.
TEXT
selected events display in text format. This is the default value. It can be
combined with TOKEN value.
TOKEN [detail]
selected events display in token format. It can be combined with TEXT value. If
present, the detail option indicates that all tokens are displayed. If the option
is not specified, the header tokens will not be displayed.
LDEV [ 0..4095 | devname ]
identifies a particular device name or number.
devname
device name (external local format), in accordance with Tandem syntax.
PROCESSID [ process-name | cpu | cpu,pin ]
identifies a particular process name or cpu or cpu,pin.
process-name
process name (external format), in accordance with Tandem syntax.
cpu
number in the range [0..15].
pin
number in the range [0..255].
SSID [ "owner.subsystem ID" ]
identifies a particular subsystem. The file EMSASSID lists the most common
Tandem subsystems (see Appendix B, EMSASSID File).
owner.subsystem ID
identification of a subsystem, in accordance with Tandem syntax. For Tandem
subsystems, owner is TANDEM, and subsystem ID is the name or number
associated to each subsystem. The version is not required.