Exchange/RJE Manual
Configuring Data Communications Lines
Installation and Configuration
104698 Tandem Computers Incorporated 6–3
PPNSW or PPSW
specify PPNSW (point-to-point nonswitched line) for a leased line.
Specify PPSW (point-to-point switched line) for a switched—dial in or out—line.
Also note that the value specified for RSIZE is informational only—it does not affect
the block size that can be transmitted.
Example Configuration
!*********************************************************************
! BISYNC MACRO FOR EXCHANGE/RJE LINE
!*********************************************************************
RJE^MACRO = BISYNC TYPE 07, SUBTYPE 01,
RSIZE 512, DRIVER SCOM6201,
PROTOCOL BSC^PROTOCOL, EBCDIC,
CRC16, NOLEADEOT,
NOCLEARCA, NOCTRLCF,
SPEED 96, SYNCS 3,
PRIMARY, MULTILEAVING, PPNSW,
THRESHOLD 100, RETRIES 3,
FULL, TIMEOUT 270 #;
!*********************************************************************
! AUTOMATIC CALL UNIT MACRO
!*********************************************************************
ACU^MACRO = ACU
TYPE 7,
SUBTYPE 56,
DRIVER ACOM6301X2,
PROTOCOL ACU^PROTOCOL,
RSIZE 32,
DTROFF #;
PERIPHERALS:
!***********************************************************************
! EXCHANGE/RJE ENVOY DATA COMMUNICATIONS LINE
!***********************************************************************
$RJE1 BYTEA.0, BYTEA.1 RJE^MACRO;
!***********************************************************************
! EXCHANGE/RJE ACU LINE
!***********************************************************************
$ACU1 ASYND.00,ASYND.01 ACU^MACRO;