Exchange/RJE Manual

Trace Server Messages
Exchange/RJE Messages
104698 Tandem Computers Incorporated A–5
RJCI12E $
server
TERMINATED WHILE ATTEMPTING TO DO THE CONNECT
Problem. The Exchange/RJE line server stopped during the execution of the
CONNECT command. Generally, this is due to the incorrect values for the
configuration parameters.
Solution. Use the SHOW command to verify the values of the configuration
parameters. Correct the values, and enter the CONNECT command again.
RJCI13E $
server
IS THE INCORRECT LINE SERVER TYPE
Problem. The name of the program file from which the line server was started is not
RJESV. Usually, this means you named an existing process in the SERVER
configuration parameter that is not an existing Exchange/RJE line server process.
Solution. Start a new line server, or restart an existing line server,using the correct
program file name.
RJCI14E I/O ERROR ON
filename
, ERROR
number
Problem. A file-system error (whose error number is
error
) occurred while
performing I/O on
filename
.
Solution. Determine the nature of the file-system error and correct the problem. You
can use the command interpreter ERROR command to see the text associated with the
error number.
RJCI15E CONFIGURATION OF $
server
DOES NOT MATCH REQUESTED
Problem. The current values of the configuration parameters do not match the values
in effect when the line server was started; the connection cannot be established.
Solution. You can change the current values of the configuration parameters to match
the values in effect when the line server was started, or you can use the CONNECT !
command.