Exchange/RJE Manual

Trace Server Messages
Exchange/RJE Messages
104698 Tandem Computers Incorporated A–7
RJCI20E
param1
AND
param2
MUST BE ON THE SAME SYSTEM
RJCI20*
param1
IS ON
system-name
,
system-number
RJCI20*
param2
IS ON
system-name
,
system-number
Problem.
param1
and
param2
are LINE and ACU, PROGRAM and SERVER, or
PROGRAM and USERLIB. Each of these parameter pairs must be specified as being
on the same system.
Solution. If a system name is specified for LINE and ACU, PROGRAM and SERVER, or
PROGRAM and USERLIB, specify the same system for both parameters.
RJCI21W THE LINECODE PARAMETER IS NO LONGER USED AND IS
IGNORED.
RJCI21* THE LINECODE TYPE IS DETERMINED BY THE SYSGEN
PARAMETERS FOR THE LINE.
Problem. The LINECODE parameter is no longer used.
Solution. To avoid this message, do not specify the LINECODE parameter.
RJCI22E CPU
cpu-number
DOES NOT EXIST OR IS DOWN
Problem. You have specified a CPU that does not exist or is down.
Solution. Enter the command again, and specify a CPU that exists and is up.
RJCI23E NONSTOP PRIMARY AND BACKUP CPUS CAN NOT BE THE SAME
RJCI23* CPUS
primary-cpu-number
,
secondary-cpu-number
Problem. You have specified the same CPU as both the primary CPU and the backup
CPU. The primary CPU and the backup CPU must be different CPUs.
Solution. Enter the command again, and specify different CPUs for the primary and
backup CPUs.