Exchange/RJE Manual

Trace Server Messages
Exchange/RJE Messages
A–8 104698 Tandem Computers Incorporated
RJCI24E PROCESS ERROR
message
Problem. The call to the NEWPROCESS system procedure to start the line server, the
send/receive server, or the trace server failed. The reason for the failure is given in the
message. If
message
is LIBRARY CONFLICT, the RJESV object file is already in use
and you have attempted to specify a user library for a new line server that is different
from the library specified by the first opener of RJESV.
Solution. If
message
is LIBRARY CONFLICT, specify the same user library as the first
opener or use another copy of RJESV. For information about other errors and how to
recover from them, see the System Procedure Errors and Messages Manual.
RJCI25 SERVER $
server
(
pid
) CREATED ON SYSTEM
system-name
Comment. A line server named $
server
has been started on
system-name
.
RJCI26W CONNECT WILL COMPLETE WHEN TRACE COMMAND INVOKED
Problem. The TRACE configuration parameter has been set ON, which requires that
the trace server be started before the connection can be completed, and the trace server
has not been started.
Solution. Use the TRACE command to start the trace server.
RJCI27 SERVER $
server
HAS
state
Comment. This message indicates that the specified line server has changed its state in
processing a request (for example, it has stopped).