Exchange/RJE Manual
Trace Server Messages
Exchange/RJE Messages
104698 Tandem Computers Incorporated A–9
RJCI28 COMMUNICATION LINK HAS BEEN ESTABLISHED WITH LINE
line-name
Comment. This message is issued when a new line server is started, and it indicates
that the connection has been established between the command interpreter, the
send/receive server, the line server, and the data communications line. This message
does not necessarily mean that the data communications line is working and
Exchange/RJE can communicate with the remote system.
RJCI30 DISCONNECTED FROM LINE SERVER $
server
Comment. The command interpreter has disconnected from the named line server.
RJCI31E NOT CONNECTED TO A LINE SERVER
Problem. You have entered a command that requires the command interpreter to be
connected to a line server, and the command interpreter is not connected to a line
server.
Solution. Use the CONNECT command to establish the connection between the
command interpreter and the line server.
RJCI32 TRACE INITIATED IN CPU
cpu-number
, PIN
pin-number
,
PROCESS NAME IS $
server
Comment. The trace server has been started.
RJCI33E COULD NOT CREATE A UNIQUE $
server
NAME
Problem. The operating system was unable to start one of the Exchange/RJE
components because a unique name could not be created for the component process.
Solution. Try the command at a later time.