Exchange/RJE Manual

Line Server Messages
Exchange/RJE Messages
A–26 104698 Tandem Computers Incorporated
Line Server Messages This subsection lists the messages issued by the Exchange/RJE line server. Some of
the messages are shown here on two lines even though the messages are displayed on
a single line on your screen.
Some message explanations indicate that you should contact your local Tandem
support office. Before calling the office, please gather the information outlined in the
section “Before Contacting Tandem,” later in this appendix.
RJSV01F EXCHANGE MICROCODE IS NOT INSTALLED ON CPU
number
Problem. The required microcode is not installed.
Solution. Install the required microcode, and then try the operation again.
RJSV02F CAN'T OPEN
type
FILE -
filename
RJSV02* FILE MANAGEMENT SYSTEM ERROR -
number
Problem. The line server was unable to open the specified file due to the file-system
error indicated by
number
.
Solution. Correct the cause of the error, and then try the operation again.
RJSV03F ILLEGAL PARAMETER
keyword
Problem. You have entered an invalid parameter in an RJESV command or your
application program gave the line server an invalid parameter in the startup message.
Solution. Refer to Section 5 for information about the parameters for the RJESV
command. Enter the command again, and specify the correct parameter.
RJSV04F NO LINE FILE SPECIFIED
Problem. No data communications line has been specified.
Solution. Specify a data communications line.