Exchange/SNA Manual
Exchange/SNA Trace Server Messages
Exchange/SNA Messages
104700 Tandem Computers Incorporated A–7
SNCI22E CPU 
cpu-number
 DOES NOT EXIST OR IS DOWN.
Problem. You have specified a CPU that does not exist or is down.
Solution. Enter the command again, and specify a CPU that exists and is up.
SNCI24E PROCESS ERROR 
message
.
Problem. Exchange/SNA is unable to start a new line server or send/receive server.
The nature of the error is indicated in 
message
.
Solution. Take appropriate operating system error recovery actions as required by the
nature of the error.
SNCI25 SERVER $
server
 (
pid
) CREATED ON SYSTEM 
system-name
.
Comment. A line server named $
server
 has been started on 
system-name
.
SNCI26W CONNECT WILL COMPLETE WHEN TRACE COMMAND INVOKED.
Problem. The TRACE configuration parameter has been set ON, which requires that
the trace server be started before the connection can be completed, and the trace server
has not been started.
Solution. Use the TRACE command to start the trace server.
SNCI27 SERVER $
server
 HAS 
message
.
Comment. Displays a message from a send/receive server.