Exchange/SNA Manual
Exchange/SNA Trace Server Messages
Exchange/SNA Messages
A–12 104700 Tandem Computers Incorporated
SNCI48E OPTION CAN NOT BE
action
WHILE CONNECTED TO A LINE
SERVER.
Problem. You have attempted to change a configuration parameter while connected to
a line server. Configuration parameters cannot be changed while connected to a line
server.
Solution. Use the DISCONNECT command to disconnect from the line server, and then
change the configuration parameter using the SET command.
SNCI49
message
.
Comment. No action is required.
SNCI50E ALL SUBDEVICES ARE BUSY
Problem. All specified subdevices are unavailable.
Solution. Try the operation again later.
SNCI51E SUBDEVICE
subdevice-name
IS BUSY
Problem. All specified subdevices are unavailable.
Solution. Either enter the command again, specifying another subdevice, or try the
operation again at a later time.
SNCI52E NO PREVIOUS
send/receive
FILE ON SUBDEVICE
device-name
Problem. You omitted the send file in a SEND command and no send file has been
specified in a previous SEND command, or you omitted the receive file in a RECEIVE
command and no receive file has been specified in a previous RECEIVE command.
Solution. Enter the SEND or RECEIVE command again and specify a send or receive
file.