Considerations
initialization of the Expand line-handler process. The path will not be operational
until you alter NEXTSYS to a valid value using either the WAN subsystem SCF
ALTER DEVICE command or the Expand subsystem SCF ALTER PATH
command.
modifier_keyword
is the name of an optional modifier in profile_name. modifier_keyword is
added to the device record for this Expand line-handler process.
Modifier names in the PEXQSSWN and PEXQSSAT profiles are listed in Profile
Modifiers on page 7-13.
modifier_value
is the value you want to assign to the optional modifier specified by
modifier_keyword. modifier_value assigns a value to modifier_keyword
in the device record for this Expand line-handler process.
Default values and ranges of values for modifiers in the PEXQSSWN and
PEXQSSAT profiles are described in Profile Modifiers on page 7-13.
Considerations
Not all modifiers have associated values (for example, L4EXTPACKETS_ON).
The modifier_keyword and modifier_value parameters do not add the
specified modifier, or a modifier and its associated value, to the profile used by the
device. Use the ADD PROFILE command to add a modifier, or a modifier and its
associated value, to a profile.
Examples
In the first example, a device named $DIR6 is created for a single-line direct-connect
line-handler process that uses a SWAN concentrator named S01. The
PATHBLOCKBYTES modifier enables the multipacket frame feature.
-> ADD DEVICE $ZZWAN.#DIR6, PROFILE SLHTER, IOPOBJECT &
$SYSTEM.SYSTEM.LHOBJ, CPU 0, ALTCPU 1, TYPE (63,5), &
RSIZE 0, PATHTF 3, CLIP 2, LINE 0, ADAPTER S01, PATH A, &
NEXTSYS 12, PATHBLOCKBYTES 1024
In the next example, a device named $SAT1 is created for a single-line satellite-
connect line-handler process that uses a SWAN concentrator named S02.
-> ADD DEVICE $ZZWAN.#SAT1, PROFILE SLHSAT, IOPOBJECT &
$SYSTEM.SYSTEM.LHOBJ, CPU 0, ALTCPU 1, TYPE (63,5), &
RSIZE 0, PATHTF 3, CLIP 2, LINE 0, ADAPTER S02, PATH A, &
NEXTSYS 14