Expand Configuration and Management Manual (G06.24+)

Configuring Expand-Over-ATM Lines
Expand Configuration and Management Manual523347-008
9-4
Topology Considerations
Topology Considerations
In a single-line configuration, you configure one Expand-over-ATM line-handler
process for each path to an adjacent node. In a multi-CPU path configuration, you
configure multiple Expand-over-ATM line-handler processes, usually in separate
processors, for each path to an adjacent node. In a multi-line path configuration, you
configure a path that consists of multiple lines between adjacent nodes.
In Figure 9-2, a single-line path is configured between node \A and node \B; a multi-
CPU path that consists of two paths is configured between node \A and node \C; and a
multi-line path that consists of three lines is configured between node \C and node \D.
Figure 9-2. Expand-Over-ATM Line-Handler Process Topology
056CDT .CDD
Single-line Path
Node \A
CPU 1
LH
CPU 0
LH
CPU 2
LH
Node \C
CPU 0
LH
Node \B
CPU 1
LH
CPU 2
LH
Multi-CPU Path
LH LH
CPU 3 CPU 1
Multiline Path
Node \D