Expand Configuration and Management Manual (G06.24+)

Configuring Expand-Over-ATM Lines
Expand Configuration and Management Manual523347-008
9-21
PEXQSATM Modifiers
TIMERRECONNECT 30 30 through 32767
TXWINDOW 7 2 through 25
1. This is a required modifier.
2. This modifier is required for Expand-over-ATM line-handler processes that use SVC connections.
3. This modifier is required for Expand-over-ATM line-handler processes that use PVC connections.
4. This modifier is required for Expand-over-ATM line-handler processes that use ATMSAP connections.
5. This is a required modifier. The default value is invalid and must be changed.
6. The maximum value is actually 9180, but for performance it is best to use whole multiples of 32, which would
result in a 9152 maximum.
7. Although the default value is COMPRESS_ON, we recommend that you turn it off for ATM.
Table 9-1. PEXQSATM Modifiers for Expand-over-ATM Lines (page 3 of 3)
Modifier Default Value Range of Values