Expand Configuration and Management Manual (G06.24+)

Configuring Expand-Over-X.25 Lines
Expand Configuration and Management Manual523347-008
10-7
Summary of Configuration Steps
Summary of Configuration Steps
Once all hardware and software requirements have been met (refer to Required
Hardware and Software on page 10-1 for details), configuring and starting a single-line
Expand-over-X.25 line-handler process involves the following steps.
Step 1: Add a NAM Subdevice to the X25AM
Line
An Expand-over-X.25 line-handler process must have access to a NAM subdevice of
an X25AM line. You use the X25AM subsystem SCF ADD SU command to configure a
NAM subdevice. For example, the following command creates a NAM subdevice
named #XNAM for an X25AM line named $X2501:
-> ADD SU $X2501.#XNAM, PROTOCOL NAM, DEVTYPE (63,0), &
RECSIZE 128, DESTADDR "3012233490", port 90
Step Tool Used
Step 1: Add a NAM Subdevice to the X25AM Line
SCF interface to the X25AM
subsystem
Step 2: Start the X25AM Line
SCF interface to the X25AM
subsystem
Step 3: Create a Profile for the Expand-Over-X.25 Line-
Handler Process
SCF interface to the WAN
subsystem
Step 4: Create the Expand-Over-X.25 Line-Handler
Process
SCF interface to the WAN
subsystem
Step 5: Start the Expand-Over-X.25 Line-Handler Process
SCF interface to the WAN
subsystem
Step 6: Start the Expand-Over-X.25 Line
SCF interface to the Expand
subsystem
Note. The SCF command syntax shown in this section is the syntax used to configure
Expand-over-X.25 line-handler processes; it is not meant to show the complete syntax of the
SCF commands described. Refer to the following manuals for more information:
X25AM Configuration and Management Manual for X25AM subsystem SCF commands
WAN Subsystem Configuration and Management Manual for WAN subsystem SCF
commands
Section 15, Subsystem Control Facility (SCF) Commands, for Expand subsystem SCF
commands
Note. The following procedure assumes that an X25AM line-handler process has already
been created. To create an such a process, you must add it as a device to the WAN
subsystem. For complete information about creating X25AM processes, refer to the WAN
Subsystem Configuration and Management Manual.