Expand Configuration and Management Manual (G06.24+)
Configuring Expand-Over-X.25 Lines
Expand Configuration and Management Manual—523347-008
10-7
Summary of Configuration Steps
Summary of Configuration Steps
Once all hardware and software requirements have been met (refer to Required
Hardware and Software on page 10-1 for details), configuring and starting a single-line
Expand-over-X.25 line-handler process involves the following steps.
Step 1: Add a NAM Subdevice to the X25AM
Line
An Expand-over-X.25 line-handler process must have access to a NAM subdevice of
an X25AM line. You use the X25AM subsystem SCF ADD SU command to configure a
NAM subdevice. For example, the following command creates a NAM subdevice
named #XNAM for an X25AM line named $X2501:
-> ADD SU $X2501.#XNAM, PROTOCOL NAM, DEVTYPE (63,0), &
RECSIZE 128, DESTADDR "3012233490", port 90
Step Tool Used
Step 1: Add a NAM Subdevice to the X25AM Line
SCF interface to the X25AM
subsystem
Step 2: Start the X25AM Line
SCF interface to the X25AM
subsystem
Step 3: Create a Profile for the Expand-Over-X.25 Line-
Handler Process
SCF interface to the WAN
subsystem
Step 4: Create the Expand-Over-X.25 Line-Handler
Process
SCF interface to the WAN
subsystem
Step 5: Start the Expand-Over-X.25 Line-Handler Process
SCF interface to the WAN
subsystem
Step 6: Start the Expand-Over-X.25 Line
SCF interface to the Expand
subsystem
Note. The SCF command syntax shown in this section is the syntax used to configure
Expand-over-X.25 line-handler processes; it is not meant to show the complete syntax of the
SCF commands described. Refer to the following manuals for more information:
•
X25AM Configuration and Management Manual for X25AM subsystem SCF commands
•
WAN Subsystem Configuration and Management Manual for WAN subsystem SCF
commands
•
Section 15, Subsystem Control Facility (SCF) Commands, for Expand subsystem SCF
commands
Note. The following procedure assumes that an X25AM line-handler process has already
been created. To create an such a process, you must add it as a device to the WAN
subsystem. For complete information about creating X25AM processes, refer to the WAN
Subsystem Configuration and Management Manual.