Expand Configuration and Management Manual (G06.24+)

Subsystem Control Facility (SCF) Commands
Expand Configuration and Management Manual523347-008
15-15
ALTER LINE Command
For detailed information about the line attributes that have corresponding profile
modifiers, refer to the description of the corresponding profile modifier in Section 17,
Expand Modifiers.
Line attributes that do not have corresponding profile modifiers are as follows:
CLBDWNLOADRETRIES integer
specifies the maximum number of times that the Expand line-handler process will
try to download a communications line interface processor (CLIP). This attribute
applies to ServerNet wide area network (SWAN) concentrators. The valid range for
this attribute is 2 to 255. The default is 3.
CLBDWNLOADTIMR time
specifies the time interval that the Expand line-handler process will wait for the
successful completion of a communications line interface processor (CLIP)
download operation. This attribute applies to ServerNet wide area network (SWAN)
concentrators only. The time interval is specified in the format described in Time
Values on page 15-6.
The valid range for this attribute is 30.00 seconds to 5:27.67 minutes. The default
is 30.00 seconds.
CLBIDLETIMER time
specifies the time interval that the Expand line-handler process will wait before
sending successive status probes to the communications line interface processor
(CLIP). A value of 0 indicates that no status probe will be issued. This attribute
applies to ServerNet wide area network (SWAN) concentrators only. The time
interval is specified in the format described in Time Values on page 15-6.
RXWINDOW RXWINDOW n
SPEED SPEED n
SPEEDK SPEEDK n
SRCIPADDR SRCIPADDR n
SRCIPPORT SRCIPPORT n
TIMERINACTIVITY TIMERINACTIVITY n
TIMERPROBE TIMERPROBE n
TIMERRECONNECT TIMERRECONNECT n
TXWINDOW TXWINDOW n
V6DESTIPADDR V6DESTIPADDR n
V6SRCIPADDR V6SRCIPADDR n
Table 15-4. ALTER LINE Attributes and Corresponding Profile
Modifiers (page 2 of 2)
SCF Attribute Profile Modifier