MAXRECONNECTS n
handler will display a configuration error. Refer to Setting Time Factors on page 18-23
for more detailed information about establishing time factors.
MAXRECONNECTS n
Default: 0
Units: Not applicable
Range: 0 through 32767
This modifier is applicable to Expand-over-NAM, Expand-over-IP, Expand-over-ATM,
Expand-over-ServerNet, and Expand-over-FOX line-handler processes.
For Expand-over-NAM, Expand-over-ServerNet, and Expand-over-FOX line-handler
processes, this modifier specifies the maximum number of times the Expand line-
handler process will try a connect request after successfully binding to the network
access method (NAM) interface.
For Expand-over-IP and Expand-over-ATM line-handler processes, this modifier
specifies the maximum number of times the Expand-over-IP or Expand-over-ATM line-
handler process will try to connect to the remote Expand-over-IP or Expand-over-ATM
line-handler process. A value of 0 indicates an infinite number of retries.
NEXTSYS n
Default: 255
Units: Not applicable
Range: 0 through 254
This path modifier is applicable to all Expand line types. This modifier specifies the
number of the system connected to the other end of the line. If you do not specify the
NEXTSYS modifier, it defaults to an invalid value (255), and an operator message
occurs during the initialization of this Expand line-handler process. The path will not be
operational until you alter the NEXTSYS modifier to a valid value using either the WAN
subsystem SCF ALTER DEVICE command or the Expand subsystem SCF ALTER
PATH command.
OSSPACE n
Default: 32767
Units: Words
Range: 3072 through 32767
This path modifier is applicable to all Expand line types. This modifier defines the
maximum buffer size for storing out-of-sequence (OOS) packets, in words. The OOS
buffer is in the data segment or the extended data segment. Networks that include