Expand Configuration and Management Manual (G06.24+)

Troubleshooting
Expand Configuration and Management Manual523347-008
21-22
Expand-Over-IP Problems
Resolving Expand-Over-IP Connection Problems
If the SCF STATUS LINE, DETAIL command displays CONNECTING in the Detailed
State field, use the SCF STATS LINE command to obtain further information about the
problem. Example 21-8 shows an SCF STATS LINE command.
If the line is configured to issue active connect requests, determine if Connect
Command frames (Conn Cmd column) are being sent (Send row). If the line is
configured in passive connect mode, determine if Connect Command frames (Conn
Cmd column) are being received (Rcvd row). If no Connect Command frames are
being sent or received, the destination line-handler process may not be operational or
there may be a network problem.
If the Invalid Frames Rcvd counter is greater than 0, frames are being corrupted;
contact your HP support representative.
If the Invalid IP Addr Rcvd counter is greater than 0, the Internet Protocol (IP) address
configured for either the local or destination Expand-over-IP line-handler process may
be invalid. Use the SCF INFO LINE command with the DETAIL option to display the
configured IP addresses and associated NonStop TCP/IP process. Example 21-9
SOCKET SETUP This is an internal state that should
not persist.
Try to restart the line. If this
state persists, contact your HP
representative.
SOCKET_SPACE This is an internal state that should
not persist.
Try to restart the line. If this
state persists, contact your HP
representative.
WAIT The Expand-over-IP line-handler
process is waiting for another
process or subsystem.
The line remains started but is not
ready for data transfer.
See the Detailed Info field for
more specific error information.
Recovering from these types of
problems is described further
in Resolving Expand-Over-IP
Wait Problems on page 21-23.
Example 21-8. SCF STATS LINE Command (Expand-Over-IP)
- > stats line $lnfij
EXPAND Stats LINE $LNFIJ, PPID ( 2, 69), BPID ( 3, 69)
Resettime... MAR 07,1997 16:06:48 Sampletime... JUN 13,2000 16:33:44
Conn Cmd Conn Resp Data Query Cmd Query Resp
Scnd 0 0 0 0 0
Rcvd 0 0 0 0 0
Invalid Frames Rcvd 0 Invalid IP Addr Rcvd 0
Frames Dropped 0 Tx Window Available 0
Mem Low 0 Line Quality 100
Table 21-11. Detailed States (Expand-Over-IP) (page3of3)
Detailed State Cause/Effect Recovery