Expand Management Programming Manual
 COMMANDS AND RESPONSES
 INFO LINE Command
 ZRETRIES contains the number of level-2 retries that are
 attempted before a failure is reported. This field corre-
 sponds to the SYSGEN modifier L2RETRIES.
 ZSPEED contains the baud rate of the line handler. This field
 corresponds to the SYSGEN modifier LINESPEED.
 ZSYNCS contains the number of leading sync characters trans-
 mitted before each frame. This field corresponds to the
 SYSGEN modifier SYNCS.
 ZTEST-INTVL contains the amount of time in microseconds
 between CLIP status probes. This field corresponds to the
 SYSGEN modifier CLBSTATUSPROBETIME.
 ZTHRES contains the number of frames that must be sent
 and received before line quality is checked. This field
 corresponds to the SYSGEN modifier LINEQUALITYTHRESHOLD.
 ZTIMEOUT contains the amount of time in microseconds that the
 level-2 T1 timer will run before timing out. This field
 corresponds to the SYSGEN modifier L2TIMEOUT.
 ZWINDOW contains the number of EXPAND packets the line handler
 can send before it receives a reply. This field has no
 corresponding SYSGEN modifier.
 ZTYPE is a pair of integers containing the device type and
 subtype of the line. The two integers of ZTYPE correspond to
 the SYSGEN modifiers TYPE and SUBTYPE.
 ZEXP-MAP-INFO-LINE-NAM is returned when the line handler is
 configured as NAM. It has the token number ZEXP-TNM-INFO-LINE-
 NAM and the DDL definition ZEXP-DDL-INFO-LINE-NAM. This token
 contains the following fields:
 ZASSOC-DEV contains the logical device name of the NAM
 process. This field corresponds to the SYSGEN modifier
 ASSOCIATEDEV.
 ZASSOC-SUBDEV contains the logical subdevice name of the NAM
 logical device. This field corresponds to the SYSGEN modifier
 NAME.
 ZDELAY contains the amount of time in microseconds between
 transmissions. This field has no corresponding SYSGEN
 modifier.
 ZFRAME-SIZE contains the frame size in words. This field
 corresponds to the SYSGEN modifier FRAMESIZE.
 7-41