Expand Management Programming Manual

COMMANDS AND RESPONSES
INFO LINE Command
ZRETRIES contains the number of level-2 retries that are
attempted before a failure is reported. This field corre-
sponds to the SYSGEN modifier L2RETRIES.
ZSPEED contains the baud rate of the line handler. This field
corresponds to the SYSGEN modifier LINESPEED.
ZSYNCS contains the number of leading sync characters trans-
mitted before each frame. This field corresponds to the
SYSGEN modifier SYNCS.
ZTEST-INTVL contains the amount of time in microseconds
between CLIP status probes. This field corresponds to the
SYSGEN modifier CLBSTATUSPROBETIME.
ZTHRES contains the number of frames that must be sent
and received before line quality is checked. This field
corresponds to the SYSGEN modifier LINEQUALITYTHRESHOLD.
ZTIMEOUT contains the amount of time in microseconds that the
level-2 T1 timer will run before timing out. This field
corresponds to the SYSGEN modifier L2TIMEOUT.
ZWINDOW contains the number of EXPAND packets the line handler
can send before it receives a reply. This field has no
corresponding SYSGEN modifier.
ZTYPE is a pair of integers containing the device type and
subtype of the line. The two integers of ZTYPE correspond to
the SYSGEN modifiers TYPE and SUBTYPE.
ZEXP-MAP-INFO-LINE-NAM is returned when the line handler is
configured as NAM. It has the token number ZEXP-TNM-INFO-LINE-
NAM and the DDL definition ZEXP-DDL-INFO-LINE-NAM. This token
contains the following fields:
ZASSOC-DEV contains the logical device name of the NAM
process. This field corresponds to the SYSGEN modifier
ASSOCIATEDEV.
ZASSOC-SUBDEV contains the logical subdevice name of the NAM
logical device. This field corresponds to the SYSGEN modifier
NAME.
ZDELAY contains the amount of time in microseconds between
transmissions. This field has no corresponding SYSGEN
modifier.
ZFRAME-SIZE contains the frame size in words. This field
corresponds to the SYSGEN modifier FRAMESIZE.
7-41