Expand Management Programming Manual
EVENT MANAGEMENT
3: ZEXP-EVT-IO-BUS-ERR
3: ZEXP-EVT-IO-BUS-ERR
An I/O-bus error occurred, and an I/O path switch took place.
This event is a critical event, and the event message is reported
to the EMS collector, $0.
This event message is equivalent to console message 03.
Unconditional Tokens
ZSPI-TKN-SSID token-type ZSPI-TYP-SSID.
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-ENUM.
ZEMS-TKN-SUBJECT-MARK token-type ZSPI-TYP-MARK.
ZEMS-TKN-LDEVNAME token-type ZSPI-TYP-FNAME32.
ZEMS-TKN-EMPHASIS token-type ZSPI-TYP-BOOLEAN.
ZEMS-TKN-CONSOLE-PRINT token-type ZSPI-TYP-BOOLEAN.
ZEMS-TKN-CPU token-type ZSPI-TYP-UINT.
ZEMS-TKN-CRTPID token-type ZSPI-TYP-CRTPID.
ZEMS-TKN-GENTIME token-type ZSPI-TYP-TIMESTAMP.
ZEMS-TKN-LOGTIME token-type ZSPI-TYP-TIMESTAMP.
ZEMS-TKN-PIN token-type ZSPI-TYP-UINT.
ZEMS-TKN-SYSTEM token-type ZSPI-TYP-UINT.
ZEMS-TKN-USERID token-type ZSPI-TYP-BYTE-PAIR.
ZEXP-TKN-SYS-MSG-MODE token-type ZSPI-TYP-INT.
ZEMS-TKN-LDEV token-type ZSPI-TYP-UINT.
ZEXP-TKN-IO-BUS-ERR token-type ZSPI-TYP-INT.
Tandem Internal Tokens
ZEMS-TKN-OPMSG token-type ZEMS-TYP-OPMSG.
Event-Message Text
Display Format:
LDEV
ldev
[ %
ccu
] I/O BUS ERROR #
nnn
(BELL)
Console-Compatible Format:
LDEV
ldev
[ %
ccu
] I/O BUS ERROR #
nnn
(BELL)
8-7