Expand Management Programming Manual
 EVENT MANAGEMENT
 4: ZEXP-EVT-DEV-ERR
 For the multifunction controller, the status word can be inter-
 preted as two bytes whose values identify the cause of the
 controller interrupt, as follows:
 Bits 0-7 Bits 8-15 Meaning
 -------- --------- -------
 0 0 No error
 1 Error in data transfer to or from
 Tandem system
 3 Transfer aborted by channel
 4 Data buffer DMA error
 5 Peripheral port chip (PPC)
 error
 6 Read parity error
 7 T-bus sequence error
 8 Port transfer error
 9 Data overrun
 10 Data underrun
 2 Controller ownership error
 All values Port number of owning port
 3 Controller in dead state (has
 not received RESETUNIT EIO from
 Tandem system)
 4 Invalid EIO instruction sent to
 controller
 All values Value of EIO control field
 5 Hard (unrecoverable) error
 (this code should never appear
 in this event message)
 6 Change in interface to modem--
 value in bits 8-15 is sum of
 the values representing all of
 the following conditions that
 apply:
 1 Data terminal ready
 2 Request to send
 4 Clear to send
 8 Carrier detect
 16 Data set ready
 7 Controller error statistics are
 being sent to I/O process
 (this code should never appear
 in this event message)
 8 Incoming frame too large
 8-14